NEWS SECTION
CTI Certified Cooling Tower
Thermal-Cell's OEM Gearbox
Thermal-Cell

After 2 years of successful field tests and applications, finally a series of selected gearbox models are incorporated into our product ranges... and more are expected to come !

Secured and Successful Works

Successful completion for DOW Thailand - Material quality & site safety, always our top priority !

 
 
Our Products
TMC offers a wide choice of quality cooling towers both counterflow & crossflow design with FRP, Steel, Wood, Concrete to suit different needs or requirements. With wide experience & knowledge, we make sure that each product fulfills the specification and quality standard as desired by our clients. We have been established close relationships with many of the equipment suppliers in the cooling tower industry therefore only high quality components are used, for better performance and a longer life cycle.

Reinforced Concrete Counterflow Cooling Tower
Thermal-Cell
 
Recommendation for all Reinforced Concrete Structural design shall provide nominal 2” (51mm) cover over reinforced steel per ACI 318, and for 5000 psi (35 MPa) compressive
strenght at 28 days.
Back To Top
HDG Steel Structure Counterflow Cooling Tower
Thermal-Cell
 
The structure consists of Mild Steel sections with the industrial type corrosion protection by Z600
galvanizing standard.

Back To Top
Reinforced Fibreglass Counterflow Cooling Tower
Thermal-Cell
 
The structure consists of pultruded fiberglass sections an all-purpose isophthalic polyester resin system with a 5-7-mil surface veil UV inhibitor applied in compliance with CTI STD-137 will be provided.
Back To Top
Pre-treated Fir Wood Structure Counterflow Cooling Tower
Thermal-Cell
 
All structural member will consist of Fir Dense #1 lumber that will be pressure treated in accordance with CTI STD 112, except moisture, with CCA treatment.
Back To Top
Pre-treated Wood Structure Crossflow Cooling Tower
Thermal-Cell
 
All structural member will consist of Fir Dense #1 lumber that will be pressure treated in accordance
with CTI STD 112, except moisture, with CCA treatment.
Back To Top
CTI Certified Cooling Tower - TYH Series
 
  • CTI Certified TYH Series Crossflow Cooling Tower
  • Top Discharge
  • Film Fill
  • Steel structure
  • Cell size from 100 m3/hr to
    1,000 m3/hr




Back To Top
Cooling Tower Parts And Components
Thermal-Cell
 
  • FAN
  • GEAR REDUCER
  • DRIVESHAFT
  • DRIVER MOTOR
  • FILLS & ELIMINATOR
Back To Top